Technical Library

Technical Documentation for GCC Commercial Projects

The Liquid Coatings by Forti Nova Technical Library provides access to technical data sheets, safety data sheets, classification documentation and application guidance for specialist coating systems used across commercial and infrastructure projects in Dubai, the UAE and wider GCC markets.

All documentation is available on request. Contact our technical team with your project details to receive the relevant documentation for specification, project records and compliance review.

Request Documentation

15 documents found

Technical Data Sheet
BelowGrade

BelowGrade — Technical Data Sheet

Full technical information for the BelowGrade spray-applied below-ground waterproofing system including application parameters, cure times, coverage rates and performance data.

Available on request Request
Safety Data Sheet
BelowGrade

BelowGrade — Safety Data Sheet (Component A)

Safety information for BelowGrade Component A covering correct site handling, storage, PPE requirements and hazard identification.

Available on request Request
Safety Data Sheet
BelowGrade

BelowGrade — Safety Data Sheet (Component B)

Safety information for BelowGrade Component B covering correct site handling, storage, PPE requirements and hazard identification.

Available on request Request
System Information
BelowGrade

BelowGrade — Two-Component System Information

Application methodology, equipment requirements, mixing ratios and quality control guidance for two-component spray-applied below-ground waterproofing.

Available on request Request
Technical Data Sheet
SprayGrade

SprayGrade — Technical Data Sheet

Full technical information for the SprayGrade commercial roof refurbishment system including application parameters, cure times, UV resistance test data and coverage rates.

Available on request Request
Safety Data Sheet
SprayGrade

SprayGrade — Safety Data Sheet (Component A)

Safety information for SprayGrade Component A for correct site handling, storage and application on commercial roof refurbishment projects.

Available on request Request
Safety Data Sheet
SprayGrade

SprayGrade — Safety Data Sheet (Component B)

Safety information for SprayGrade Component B for correct site handling, storage and application on commercial roof refurbishment projects.

Available on request Request
Technical Data Sheet
TopSpray35

TopSpray35 — Technical Data Sheet

Full technical information for the TopSpray35 metal roof refurbishment system including substrate suitability, application parameters and anti-corrosive performance data.

Available on request Request
Safety Data Sheet
TopSpray35

TopSpray35 — Safety Data Sheet

Safety information for TopSpray35 covering correct site handling, storage, PPE requirements and application safety guidance.

Available on request Request
Technical Data Sheet
FireGuard Pro200

FireGuard Pro200 — Product Data Sheet (PDS)

Full technical information for FireGuard Pro200 including substrate suitability, application parameters, layer thickness, cure data and performance information.

Available on request Request
Safety Data Sheet
FireGuard Pro200

FireGuard Pro200 — Safety Data Sheet (Base Component)

Safety information for FireGuard Pro200 base component for correct site handling, storage and application safety.

Available on request Request
Safety Data Sheet
FireGuard Pro200

FireGuard Pro200 — Safety Data Sheet (Hardener Component)

Safety information for FireGuard Pro200 hardener component for correct site handling, storage and application safety.

Available on request Request
Classification Document
FireGuard Pro200

FireGuard Pro200 — Classification Report No. 18831B

Warringtonfire Gent Classification Report No. 18831B for FireGuard Pro200 — A2-s1,d0 fire classification to EN 13501-1:2007+A1:2009. Available on request for specification, project documentation and compliance review.

Available on request Request
Application Guidance
All Systems

Application Guidance — Spray-Applied Systems

General application guidance for spray-applied two-component coating systems — covering equipment setup, environmental conditions, substrate preparation and quality control.

Available on request Request
Application Guidance
All Systems

Substrate Preparation Guide

Guidance on substrate preparation requirements for spray-applied waterproofing and protective coating systems — covering concrete, metal and composite surfaces.

Available on request Request

System Comparison

Liquid-Applied Systems vs Traditional Alternatives

The table below compares liquid-applied coating system characteristics against traditional membrane and coating alternatives across attributes relevant to asset lifecycle and performance in GCC climates. All stated characteristics refer to documented product data and independent test evidence. This table does not constitute project-specific technical advice.

AttributeLiquid-Applied Systems
(BelowGrade / SprayGrade / TopSpray35 / FireGuard Pro200)
Traditional Alternatives
Application method
Spray-applied — seamless, no joints or laps
Sheet membranes: lapped and bonded; torch-applied or cold-adhesive
Seam / joint vulnerability
None — monolithic film with no seams
Seams and laps are primary failure points; prone to lifting and delamination
UV resistance (roof applications)
SprayGrade tested to ASTM G-155 accelerated UV weathering
Standard bituminous membranes degrade under sustained UV without additional protection
Thermal movement tolerance
Elastomeric formulation accommodates substrate movement and thermal cycling
Rigid or semi-rigid membranes can crack or debond under repeated thermal expansion in GCC climates
Below-ground chloride resistance
BelowGrade provides a continuous barrier; tested for chloride ingress resistance
Bituminous or cementitious coatings may allow chloride ingress at joints or defects
Metal substrate corrosion protection
TopSpray35 — anti-corrosive, UV-stable; suited to coastal and industrial GCC environments
Conventional paint systems require multiple coats and more frequent maintenance cycles in corrosive environments
Passive fire classification
FireGuard Pro200 — A2-s1,d0 to EN 13501-1:2007+A1:2009; independently tested by Warringtonfire Gent (Report No. 18831B)
Classified fire performance depends on product and test evidence; not all surface coatings carry independent classification
Disruption to operations
Cold-applied; no open flame; can be applied to occupied or operational buildings
Torch-applied systems require hot works permits; bituminous odour and fire risk may restrict use on occupied buildings
VOC content
VOC-free formulations (BelowGrade, SprayGrade)
Solvent-based systems may contain VOCs; restrictions apply in some GCC project specifications
Replacement vs refurbishment
Liquid-applied systems can be applied over existing substrates — avoids full removal and disposal
Full membrane replacement involves strip-out, disposal and extended programme

All product characteristics refer to manufacturer technical data and independent test documentation. Contact the technical team for system-specific data sheets and test reports.

Documentation Requests

How to Request Documentation

All technical documentation is available on request. Contact our technical team with your project details — system of interest, project type and location — and we will provide the relevant documentation promptly.

  • Technical Data Sheets available for all systems
  • Safety Data Sheets available for all systems and components
  • FireGuard Pro200 Classification Report available for specification
  • Application guidance available on request
Request Documentation